选择 | 图片 | 产品详情 | 单价 | 可用性 | ECAD 模型 | Mounting Type | Voltage - Isolation | Voltage - Input | Applications | Power (Watts) | Standard Number | Type | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Efficiency | Operating Temperature | Features | Number of Outputs | Current - Output 1 | Current - Output 2 | Approval Agency | Current - Output 6 | Current - Output 4 | Current - Output 5 | Current - Output 3 | Series | Size / Dimension |
---|
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 5V | 12V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 15 A | 6 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 5V | -5.2V | 15V | -15V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 4 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | 2 A | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 5V | 3.3V | 15V | -15V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 4 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | 2 A | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 5V | -5.2V | 12V | -12V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 4 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | 2 A | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 5V | 12V | 15V | -12V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 4 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | 2 A | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 5V | 12V | - | -12V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 3 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 5V | 12V | 15V | -15V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 4 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | 2 A | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 5V | 12V | 15V | -12V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 4 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | 2 A | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 5V | 24V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 12V | -12V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 7.5 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 3.0 ~ 3.3V | - | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 1 | 30 A | - | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 15V | -15V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 5 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 5V | 12V | - | -12V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 3 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 5V | 15V | - | -15V | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 3 | 15 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | 2 A | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 15V | - | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 1 | 10 A | - | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 28V | - | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 1 | 5.4 A | - | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Enclosed | 48V | - | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 1 | 3.1 A | - | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.92" H (177.8mm x 101.6mm x 48.8mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 15V | -15V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 5 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 12V | -12V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 7.5 A | 5 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) | |||
联系我们 | 联系我们 | PCB Symbol, Footprint & 3D Model | Chassis Mount | - | 85 ~ 264 VAC | ITE (Commercial), Medical | 150W | 60601-1; 62368-1 | Chassis | 5V | 12V | - | - | - | - | 74% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | 2 | 15 A | 6 A | CE, cURus, TUV, UKCA | - | - | - | - | CE-150 (150W) | 7.00" L x 4.00" W x 1.75" H (177.8mm x 101.6mm x 44.5mm) |
告诉我们您在找什么?